E71T-GS vs. E71T-11: Which Gasless Flux Cored Wire Is Right for Your Job?
When a secondary shielding gas isn’t practical, self shielded flux cored wire is the answer. Two of the most common choices are E71T-GS and E71T-11. Both are all position wires for mild steel, and both run without a gas cylinder, but they are built for different jobs. Here’s how to tell them apart.
E71T-GS: the single pass specialist
E71T-GS is designed for single pass, all position welds on mild steel, including fabrication, erection, and repair work in the field. It’s especially at home on thin mild steel and galvanized sheet metal.
- Smooth, stable arc with low spatter and easy slag removal
- Relatively light penetration, which helps eliminate burn through on thin material
- Tolerates rust, dirt, and oil on the workpiece
- Weld deposit resembles that of E6011 electrodes
- Typical as welded properties: 75,000 psi tensile strength, 22% elongation, and no defects in the longitudinal guided bend test
- Limited to nonstructural applications
If your work is sheet metal, maintenance, or repair on thinner steel, E71T-GS is built for it.
E71T-11: more range for fabrication
E71T-11 is also a general purpose wire, but it adds flexibility. It handles single pass welds on thinner gauge material and limited multi pass welds on thicker sections, on both mild and galvanized steel.
- Multi pass welds on plate up to 3/8″ (9.5 mm)
- Smooth arc, full slag coverage, low spatter, and great bead appearance
- Suited to general fabrication, prefab construction, tank and railcar repair, and light structural work
- A great choice for field repair of fences, parts, and machinery
Quick comparison
- Passes: E71T-GS is single pass only. E71T-11 covers single pass plus limited multi pass.
- Material thickness: E71T-GS is aimed at thin mild and galvanized steel. E71T-11 extends to plate up to 3/8″ with multi pass welds.
- Applications: E71T-GS is for nonstructural work. E71T-11 includes light structural work.
- Weld chemistry: E71T-11 runs higher in manganese (1.55 vs. 0.82), while E71T-GS runs higher in carbon and silicon.
How to choose
- Is it one pass or more? If the joint needs multiple passes, go with E71T-11.
- How thick is the steel? Thin sheet points to E71T-GS. Thicker sections, up to 3/8″, point to E71T-11.
- Is it structural? E71T-GS should stay in nonstructural applications. For light structural work, E71T-11 is the better fit.
As always with self shielded wire, make sure you have good ventilation, especially on galvanized steel.
Washington Alloy offers E71T-11 in .030, .035, .045, 1/16, and 5/64 diameters, from 2 lb spools up to 33 lb spools. Not sure which wire fits your application? Call us at (800) 830-9033 or visit washingtonalloy.com and our team will help you match the right wire to the job.
#Welding #FluxCoredWire #Fabrication #WashingtonAlloy #WeldingSupplies